floodlighting for rugby pitches and grounds Sports Floodlighting

 

 

Company Profile
The Schemes
Ordering Dimensions
Column Technical Data
Contact Us

 

 

 

 

 

 

 

 

 

 

 

   
Rugby Floodlighting
 
Floodlighting for Rugby Pitches and Grounds
 
rugby pitch floodlighting scheme
 
Our Floodlighting for Rugby Pitches and Grounds adhere to the RFU guidelines.
 
  Rugby 250 Lux Floodlighting
 Pitch Dimensions  55 x 91.4m  55 x 101m
 Total Playing Area  63 x 121.4m  63 x 121.4m
 Calculation Points  11 x 21  11 x 21
 Lamp Type  HQI-TSL 2kW
 Initial Lamp Lumens  225,000
 No. of Floodlights  16
 No. of Columns  6
 Mounting Height  15
 Maintained Average Illuminance  250  252
 Initial Average Illuminance  287  290
 Uniformity (min/ave)  0.4  0.61
 Uniformity (min/max)  na  0.36
 Glare rating (max)  55  51
 
 
  Column Technical Data 15MDBH

 Design Note ** Columns are designed in accordance with ILE TR7.The normal max weight  and  wind area of the floodlight has been calculated using a wind speed and altitude  application for  90% of the UK. When the column is to be installed in an exposed site such  as a costal location, or  a site subject to local funneling, or a site 250m above sea level  advice should be sought from  SMC.

 Columns Height: (M)

 15

 Max. Total Supported Wind Area Sq.m

 1.2m²

 Max. Total Supported Weight Kgs.

 150

 Anchor Bolt Diameter (mm)

 30

 Anchor Bolt Quantity

 4

 Gear Compartment (mm)

 175x250x700

 Estimated Footing Size (M)

 2.4SQRX0.97H

lighting for rugby grounds and pitches

 

     
    Click to access 15MDBH Technical Data PDF
     
    Contact us about floodlighting for rugby pitches and grounds