Tennis Floodlighting Scheme 3 (Standard used: LTA) |
| |
| Pitch Dimensions |
11 x 24m |
| Total Playing Area |
32 x 36m |
| Calculation Points |
5 x 3m |
|
|
|
 |
| |
| Lamp Type |
1 kW MHN-LA |
| Initial Lamp Lumens |
100,000 |
| No. of Floodlights |
12 |
| No. of Columns |
6 |
| Mounting Height |
8 |
|
 |
| Maintained Average Illuminance |
400 |
450 |
| Initial Average Illuminance |
500 |
565 |
| Uniformity (min/ave) |
0.7 |
0.93 |
| Uniformity (min/max) |
0.5 |
0.84 |
| Glare rating (max) |
55 |
49 |
|
| |
In this scheme both courts must be lit. |
|
|
| |
Column Technical Data 8LDTBH |
| |
Design Note ** Columns are designed in accordance with ILE TR7.The normal max weight and wind area of the floodlight has been calculated using a wind speed and altitude application for 90% of the UK. When the column is to be installed in an exposed site such as a costal location, or a site subject to local funneling, or a site 250m above sea level advice should be sought from SMC. |
Columns Height: (M) |
8 |
Max. Total Supported Wind Area Sq.m |
1.2m² |
Max. Total Supported Weight Kgs. |
80 |
Anchor Bolt Diameter (mm) |
24 |
Anchor Bolt Quantity |
4 |
Gear Compartment (mm) |
115x135x600 |
Estimated Footing Size (M) |
1.4SQRX0.97H |
|
| |
| |
Click to access 8LDTBH Technical Data PDF |
| |
Contact us about tennis court floodlighting |
| |
| | |